Thermoplastic LED Exit Signs

Thermoplastic LED exit signs with UL 924 listings, 90 minute battery backup, and red or green letters, in stock and ready to ship with free shipping on every order when a violation deadline is running. NFPA 101 placement and battery rules are covered below the products.

Products List

Sort By:

Display Type:
Filters
  • Product
  • Qty in Cart
  • Quantity
  • Price
  • Subtotal
  • Total: items /

Adding your products to cart

Thermoplastic LED Exit Sign Buying Guide

LED Exit Signs That Pass Inspection

Exit signs get bought two ways: off a plan set, or after a fire marshal wrote up a violation with a correction deadline. Either way, the compliance details decide the order, so they go first here, and the deadline case is why this category runs on stocked product: live stock status on each product page, in-stock signs shipping within 24 hours, free, no minimums.

Start with the listing. UL 924 is the safety standard for emergency lighting and power equipment, and UL 924 listed LED exit signs have been verified for letter legibility, illumination, and 90 minutes of emergency operation. Inspectors look for the listing mark; unlisted bargain signs fail the walkthrough regardless of how bright they are.

Red or Green Letters: How the Color Gets Decided

The model codes do not pick a color. Under the IBC and NFPA 101, red and green are both acceptable unless the local jurisdiction amends the rule, and many do: New York City and Chicago, for example, mandate red, while a number of jurisdictions that carried forward older state code language standardize on green. The reliable process is short: check the local amendment or ask the AHJ before ordering, and in an existing building, match the signage already on the walls unless the AHJ says otherwise. Both letter colors are stocked here in single-face and double-face configurations with field-installable chevrons.

Exit Sign LED Light Draw and Battery Backup

An LED exit sign draws roughly 1 to 5 watts continuously, against 15 to 40 watts for the incandescent signs still hanging in older buildings, which is why a re-lamp pays for itself on a device that runs 8,760 hours a year. Battery-backed models use a sealed rechargeable pack sized for the 90 minute requirement; self-diagnostic versions run their own monthly and annual tests and show a fault code when a battery ages out, worth the small premium for any facility without a disciplined testing routine. Thermoplastic housings specifically are the economy workhorse: light, corrosion-free, and right for dry interior spaces like offices, schools, and retail. Damp or wet spaces need gasketed Wet Location Exit Signs, and abuse-prone corridors and gyms justify die-cast housings or a wire guard.

Exit lighting rarely travels alone on a violation notice. Combination units in Combination Exit and Emergency Lights put the sign and egress heads in one box, standalone egress units live under Emergency Lights, and the full range of housings and styles is in the Exit Signs parent category.

NFPA 101 Placement and Battery Rules

RequirementWhat the Life Safety Code Calls For
VisibilitySigns placed so no point in the exit access exceeds the sign's rated viewing distance; 100 feet is the standard listing
LetteringEXIT in letters at least 6 inches high with 3/4 inch stroke width
PlacementAt exits, and along the path with directional chevrons wherever the way to the exit is not obvious
Emergency power90 minutes of illumination from battery or an emergency power source
TestingA 30 second functional test monthly and a full 90 minute discharge test annually, with records kept for the AHJ

Frequently Asked Questions About Thermoplastic LED Exit Signs

UL 924 is the safety standard for emergency lighting and power equipment. A listed exit sign has been tested for letter legibility, illumination levels, and the ability to stay lit for 90 minutes on emergency power. Inspectors and AHJs look for the UL 924 mark during walkthroughs, and unlisted signs are a common correction item regardless of how they look.

The IBC and NFPA 101 accept either color, but local jurisdictions often amend the rule: New York City and Chicago require red, and some jurisdictions standardize on green. Check the local building code amendment or ask the fire marshal before ordering, and match the existing signage in an occupied building unless directed otherwise. Getting the color wrong means reordering the whole floor.

The Life Safety Code requires a 30 second functional test monthly and a full 90 minute discharge test annually, with written records available to the inspector. Self-diagnostic models automate the schedule and display a status LED or fault code, which converts the monthly obligation into a glance at the indicator during a normal walkthrough.

Standard listed exit signs are rated for 100 feet of viewing distance, and NFPA 101 requires placement so no point in the exit access is farther from a visible sign than its rating. Long corridors, turns, and obstructions therefore add signs with directional chevrons along the path. Letter size backs this up: 6 inch letters with 3/4 inch stroke width minimum.

Exit signs must stay illuminated for at least 90 minutes when normal power fails. Battery backup inside the sign is the usual way to meet that, but buildings with generators or central inverter systems can serve AC-only signs from the emergency source instead. On a standalone retrofit with no emergency power infrastructure, the battery-backed model is the safe default.

Standard thermoplastic signs are built for dry interior spaces: offices, schools, retail, and similar conditioned areas. Parking garages, canopies, kitchens, and washdown areas call for gasketed wet location rated signs instead. The location rating is on each product's spec sheet, and the spec sheet governs; a dry-location sign in a damp space is both a failure point and an inspection finding.

When the same wall or corridor position needs both the sign and egress illumination, a combination unit covers both requirements from one box, one circuit connection, and one battery, which is cheaper to buy and faster to install than two devices. Standalone signs make more sense where emergency heads already exist or where the sign hangs from a ceiling position away from the egress lighting.